Intelix FLX-44 Manual do Utilizador Página 29

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 32
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 28
FLX-44 Installaon Guide
29
HDCP Commands
/%I/04:0.
Turn HDCP Compliance o for input 4
Descripon Command Response
Turn HDCP Compliance o for input xx
/%I/xx:0. /%I/xx:0.<CR><LF>
Turn HDCP Compliance on for input xx
/%I/xx:1. /%I/xx:1.<CR><LF>
Example:
Remote RS232 Control via Roung
The FLX-44 has the logic to pass RS232 commands to remote devices through the TCP/IP or DE9 RS232 ports. The
desnaon command string is embedded in a command which includes the desnaon HDBaseT output port and
baud rate. This is a bidireconal communicaon method. The maximum string length is 48 bytes (characters). In
addion to immediate transmission, the FLX-44 can store commands to be broadcast when the matrix is powered
on or o through the standby commands (PWON. and PWOFF.).
The format of the RS232 roung string is: /+<Y>/<B>:<$>. (The period at the end of the string is required.)
<Y> is the output code, <B> is the baud rate, and <$> is the RS232 string. Output codes and baud rate codes are
in the tables below.
Baud Baud Code
2400 1
4800 2
9600 3
19200 4
38400 5
57600 6
115200 7
Output Code Timing
1
1 Immediate TX
A PWON command
E PWOFF command
2
2 Immediate TX
B PWON command
F PWOFF command
3
3 Immediate TX
C PWON command
G PWOFF command
4
4 Immediate TX
D PWON command
H PWOFF command
ALL 5 Immediate TX
/C+/4:PowerOn.
Send the string PowerOn to output 3 at 19200 baud when the matrix is powered
on.
/C+/4:.
Clear power on seng for output 3.
Examples: